Air & Surface Sanitiser
Find out more about HyGenikx Click here for replacement lamps
The HyGenikx Air and Surface Sanitisation System removes harmful viruses and bacteria from the air and on surfaces improving hygiene and cleanliness. The HyGenikx covers a wide range of sanitisation applications, including communal areas, kitchen and food preparation areas, toilets, changing rooms and refuse/bin stores. HyGenikx is a compact wall unit that can be plugged into a standard electrical socket or wired into a fused spur. It is perfect for all air surface sanitiser needs and to be retro fitted into an existing area or be built into a building design or redesign from new.
Use the HyGenikx Selector Tool to choose the HyGenikx unit best suited to your needs
HyGenikx removes harmful viruses, killing bacteria and improving safety across a wide range of hospitality and shared work and living spaces. It's compact design means it can be fitted into an existing an space or designed into a project from new.
How does a HyGenikx Air Surface Sanitiser work?
In 8 Hours, a single surface or airborne micro can multiply to over 8 Million, meaning that health risks and odours remain a major problem. The HyGenikx unit uses a combination of advanced technologies, UVGI and Titanium Dioxide to create disinfecting Plasma Quatro which kills harmful viruses. Standard room cleaning and disinfecting procedures can only offer a temporary solution, but HyGenikx air surface sanitiser is continuous, operating 24/7.
HyGenikx is an advanced and compact, wall mounted air surface sanitiser, utilising advanced technologies. Kills micro-organisms, bacteria, viruses, moulds, fungi and volatile organic compounds (VOC’s).
HyGenikx Range and Applications
HyGenikx units are an effective solution that improves infection control, removes unpleasant odours, reduces cross contamination and extents food shelf life by up to 50%. (please see Testing and efficacy data). HyGenikx air surface sanitisation systems are easy to maintain an audible alarm will sound to notify when the unit's Lamp needs replacing. Lamps are simple to replace as the units are fitted with a cut-off safety switch to protect the person and the unit.
Communal Areas, Restaurants, Bars
The HyGenikx ‘O’ range are design for smaller areas of continuous occupation, for example office space, communal living spaces or social spaces including dining areas and bars. By installing HyGenikx air surface sanitiser people can see the steps taken to protect space improving staff and customer confidence. The HyGenikx air surface sanitiser comes in a range of sizes from 10 to 30 sqm and are finished in either white or titanium exterior.
The HyGenikx ‘AF’ range are design for larger area of continuous occupation, for example office areas, communal living spaces or social spaces including dining areas and bars. The 'AF' Air and Surface Sanitiser unit features a fan that increases through put of air into the unit to deliver healthier air quality across a larger enclosed spaces. HyGenikx 'AF' air surface sanitiser comes in a range of sizes from 25 to 100 sqm and are finished in a stylish silver exterior.
Kitchen & Food Preparation Areas
The HyGenikx ‘F’ range are designed for food preparation areas and food storage, including chilled food storage areas. The 'F' range is ideal for busy kitchen areas as there are no moving parts and includes a shatter-proof food safety Lamp in compliance with kitchen regulations. The Units ability to neutralise bacteria and fungi removes odours from the kitchen space with the added benefit of extending the shelf life of fresh food.
HyGenikx also plays a key role to protect your kitchen operation from cross contamination as the air from the unit lands on exposed surfaces acting as a surface sanitiser, again, neutralising volatile organic compounds and unwanted bacteria. The HyGenikx air surface sanitiser comes in a range of sizes from 10 to 30 sqm and are finished in either white or titanium exterior.
More details of the units performance can be found in the testing and efficacy data section below where multiple laboratories have tested HyGenikx effectiveness.
Toilets, Washrooms & Changing Rooms
The HyGenikx ‘S’ range are designed for toilets, washrooms, changing rooms and locker areas. The units proven ability to destroy bacteria and organisms that cause unpleasant odours makes it the ideal solution for creating healthier enclosed spaces. The HyGenikx air surface sanitiser comes in a range of sizes from 10 to 30 sqm and are finished in either white or titanium exterior.
Refuse Areas & Bin Stores
The HyGenikx ‘R’ range are designed for non-occupied Refuse/Bin Store a key part of an operation where there is a greater need for odour control. These powerful units deal with source of airborne odours not just masking them but eradicating them at source. The HyGenikx air surface sanitisers come in a range of sizes from 10 to 30 sqm and are finished in either white or titanium exterior.
Find out more about HyGenikx
HyGenikx units are built by Mechline Development Ltd, contact information is available here.
Testing and Efficacy Data
HyGenikx air surface sanitisation system uses advanced technologies that have been tested and proven effective against Bacteria, viruses, micro organisms and volatile organic compounds. HyGenikx Meets International Emissions Standards and HyGenikx is certified for UKCA and CE.
Full testing and efficacy data can be found here on our website.
Dual Waveband
A very small volume of ozone is released as a by-product of the combination of technologies used. This unique combination of technologies is guaranteed to both achieve results and be completely safe in operation. In every case the ozone levels present fall well below the lowest international safety levels worldwide (World Health Organization - 0.05ppm), as stipulated by EUOTA. This has been verified for all unit variations with independent laboratory testing carried out by “Odournet”.
HSE UK - COSHH – For areas of Continuous occupation – HSE limit 0.1ppm
World Health Organization – Continuous occupation desired level – 0.05ppm
The US OSHA [Occupational Safety Health Act] website cites several ACGIH (American Conference of Governmental Industrial Hygienists) guidelines for ozone in the workplace:
0.2ppm for no more than 2 hours exposure
0.1ppm for 8 hours per day exposure doing light work
0.08ppm for 8 hours per day exposure doing moderate work
‘Fresh Air’ – Ozone level 0.013ppm
After a Thunderstorm – Ozone levels measured between 0.3 and 0.05ppm
HyGenikx units – Sized for appropriate areas – Ozone levels 0.03ppm [Max 0.04ppm].[Kiel Laboratories Germany. ISO Sensory / Odour Test. ISO Audited]