STANDARDS/LEGISLATION
- Kitemark License #KM39643
- Certified to BS 669-2: 1997
- Worldwide accreditation
The only hose that carries the BSI kitemark that signifies ongoing quality testing rather than the BS669 Part 2 Certificate which purley signifies compliance of one sample on the orginal test date.
CORRECT INSTALLATION
- QD part of the hose should be at the supply end
- Ensure that there is a natural, single loop - no sharp bends, crimps or twists in the hose - to avoid fatigue
- Do not allow hose to drag on the floor
- The restrainer should be slightly shorter than the the length of the gas hose to avoid over-extending the hose - do not attach restrainer to gas supply pipes, gas hose or any point of insufficiently anchored
Only braided gas hoses are used to create the Safety System Plus™. Braided hoses resist the wear & tear that can stretch other hoses and cause the hose to deteriorate over time.