GreasePaK DMi dispensing unit operation and maintenance
instructions |
 |
How it works
The GreasePaK DMi is a biological drain
maintenance syst4em designed to work only with GreasePaK
MSGD5 fluid. GreasePaK MSGD5 is a highly active fluid, specially
formulated to degrade fats and greases found in commercial
kitchen drains. GreasePaK DMi is factory set to automatically
deliver a medium dose of MSGD5 fluid into the drain at 1
am each night.instructions on how to change the factory
settings are at the bottom of this page. Because MSGD5 fluid
forms a microscopic lining on the drainage pipe work and
is more effective the longer it is left undisturbed, this
is best done when the kitchen operation is finished. For
example, if the kitchen closes at 6pm each night, the DMi
should be set to dose at 6.30 pm. The fluid can then work
uninterrupted until the kitchen operation resumes and other
fluids are flushed through the drainage system.
Important:
GreasePaK is a drain maintenance system,
not a drain unblocking system,. If being fitted to existing
drains, the drainage pipe work must be properly cleaned
and pressure washed prior to installation. Failure to do
this could result in dislodged fats and greases blocking
the drainage system further downstream. GreasePaK cannot
compensate for incorrectly sized or installed drainage pipe
work.
Location
Follow the location advice sheet supplied
with each DMi. GreasePaK can be used to prevent grease build
up at a particular point in the drainage system or in a
drain line. It may therefore be necessary to install more
than one GreasePaK DMi in a kitchen if multiple grease risk
areas are identified. Avoid connecting the dosing point
within 2 m of sources of heat or harsh chemicals within
the drainage system such as dishwashers, combination ovens,
waste disposal units, etc.
Changing the GreasePaK MSGD5 fluid pack
On the medium factory setting each 5l fluid
pack will last approximately 28 days. After this time, the
fluid pack will require changing. There is an easy way to
read fluid level indicator situated in the front cover of
t he DMi. Contact information for replacement fluid is situated
inside the DMi cover.

GreasePaK MSGD5 fluid is supplied with
a unique, easy to handle 5l fluid pack. Each fluid pack
weighs 5.5 kg, and has an individual carrying handle that
is alosused to hang the pack in the DMi. Each fluid pack
is fitted with a simple non-spill co nnector. Full instructions
on how to change the 5l fluid pack are printed on the front
of each fluid pack. Each DMi is supplied with magnetic door
catches and a key lock. If the key lock is to be used, keep
the keys in a safe, easily accessible place.
GreasePaK Operation
GreasePaK MSGD5 is a highly active bio-enzymatic
fluid. It is therefore not necessary to put bleach or harsh
chemicals into the drainage system that GreasePaK is to
maintain. To ensure best performance from the GreasePaK,
do not introduce bleach or other harsh chemicals into the
drainage system, as the effectiveness of the GreasePaK fluid
will be compromised.

Cleaning the DMi unit
The DMi has been designed for easy cleaning.
After changing the 5l fluid pack and as part of the kitchen
cleaning program, carefully wipe the DMi using clean water
and a disposable cloth. Do not use harsh cleaning chemicals.
Changing the DMi battery pack
In order to allow the GreasePaK DMi to
be situated in the mot appropriate location in the kitchen,
it is battery operated. Mains powered version is available
on request. The DMi has been designed to provide a minimum
battery life of 12 months. As the battery life nears the
end, the low battery light visible through the front cover
will begin to flash red. Contact the number on the inside
front for a replacement battery pack. Full installation
instructions are provided with the battery pack.
Changing the factory settings
The DMi is factory set to deliver a medium
dose of fluid at 1am each night. The delivery time and volume
can be changed to suite the individual kitchen requirements.
In kitchens where a high level of cooking and processing
takes place, it is advisable to change the dosing volume
to high or extra high. To change the factory settings after
installation, remove the electronics cover and follow the
instructions on the inside of the cover. Carefully replace
the electronics cover after completion, taking care to position
the low battery light.
|